beautypg.com

FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 389

background image

iRMC S2/S3

389

IPMI OEM Commands supported by the iRMC S2/S3

01 16 - Get Power Off Source

This command returns the reason for the most recent Power Off. The possible
reasons are listed below.

Request Data

-

B8

NetFnlLUN: OEM/Group

-

01

Cmd : Command Group Communication

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

16

Command Specifier

Response Data

-

BC

-

01

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first

3

01

Data Length

4

Power off Source: Cause of last power off

Power off

Source

Description

0x00

Software (SWOFF, power off by command)

0x01

Power switch (on the front panel or keyboard)

0x02

AC power fail

0x03

Clock or timer (hardware RTC or software timer)

0x04

Fan failure

0x05

Critical temperature

0x08

Final power-off after repeated watchdog timeouts

0x0C

Final power-off after repeated CPU errors

0x1D

Powered off by remote control via remote manager