iRMC
S2/S3
Power Management
●
System Identification LED
As long as the System Identification LED is on, the iRMC S3 will not
enable
0 Watt
mode.
●
Advanced Video Redirection (AVR)
If an AVR session is currently active, the iRMC S3 will not enable
0 Watt
mode. Once all AVR sessions have been finished (i.e, no AVR
is active), the iRMC S3 will enable
0 Watt
mode.
●
Remote Storage Server (RSS), Telnet/SSH Sessions
If an RSS session or an SSH/Telnet session is currently active, the
iRMC S3 will not enable
0 Watt
mode. This prevents the remote
interface connections to the iRMC S3 from being lost.
●
AC power fail
If an AC fail occurs and the PSU (Power Supply Unit) is in the
0 Watt
mode or in the scheduled mode, the PSU will return to system
standby. Depending on the power restore policy settings (see
), the iRMC S3 determines whether the server is to be
powered on. If the power restore policy is set to
Always power off
, an
AC fail will never result in
0 Watt
mode.
0 Watt
mode may be reached
after the next system power on.
Scheduled
Enables
0 Watt
mode and also displays the
0 Watt Technology
Administration Window
. The
0 Watt Technology Administration Window
allows
you to specify a time interval at which the PSU is awoken from
0 Watt
mode and thus both remote management and Wake-on-LAN (WOL) can
be used.
Figure 108: Power Options page, 0 Watt Technology Administration window
Start Time
Defines the beginning (
hh:mm
) of the time interval.