beautypg.com

Scci-compliant signaling command – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual

Page 395

background image

iRMC S2/S3

395

IPMI OEM Commands supported by the iRMC S2/S3

12.1.2.4 SCCI-compliant signaling command

10 02 - Write to System Display

This command is used to write characters to the LocalView display (if
connected).

Request Data

-

B8

NetFnlLUN: OEM/Group

-

10

Cmd : Command Group Fan Test

1:3

80 28 00

IANA-Enterprise-Number FTS, LS byte first

4

02

Command Specifier

5

Object Index: : Line on Display to write on.

6:7

Value ID (not

used)

8

Length Number of characters to write, incremented by
one. (The string need not be null-terminated; characters
exceeding the length of a display line are truncated.)

9

Attribute:

0 = Write String left aligned.

1 = Write String centered.

10:10+n

Characters to write to the display; string need not be null-
terminated.

Response Data

-

BC

-

10

1

Completion Code

2:4

80 28 00

IANA-Enterprise-Number FTS, LS byte first