Updating firmware images
10.3.3 Online update using ServerView Update Manager
Express or ASP
Under Windows and Linux operating systems, you can update the iRMC S2/S3
firmware either using the graphical user interface of ServerView Update
Manager Express or by using the ASP (Autonomous Support Package)
command interface.
Under Windows, you can also start an ASP in the Windows Explorer by double-
clicking the corresponding ASP-*
.exe
file.
I
When downgrading the firmware, please note:
–
Downgrade via Update Manager Express:
The firmware downgrade is only feasible in the
Expert
mode. In
addition, the
Downgrade
option must be activated.
–
Downgrade via ASP:
–
Under Windows:
You can perform the downgrade if you start the ASP by double-
clicking the corresponding
*.exe
file. When starting the ASP via the
CLI, you must explicitly specify the
Force=yes
option.
–
Under Linux:
You must explicitly specify option
-f
or option
--force
.
For more detailed information on firmware updates with Update Manager
Express and ASP, see the “Local System Update for PRIMERGY Servers”
manual.