iRMC S2/S3

213

Sensors - Check status of the sensors

Fan Test - Test fans

The

Fan Test

group allows you to specify a time at which the fan test is started

automatically or to start the fan test explicitly.

I

Instead of the formerly used full speed testing, most new systems now
provide a modified fan test feature which performs the fan test with a
speed near to the currently required speed. In this case, the fan test is no
longer acoustically noticeable.

Fan Check Time

Enter the time at which the fan test is to be started automatically.

Disable Fan Test

Select this option to disable fan testing.

Ê

Click

Apply

to activate your settings.

Ê

Click

Start Fan Test

to start the fan test explicitly.

System Fans - Specify server behavior in the event that a fan fails

The

System Fans

group provides you with information on the status of the fans.

You can use the options or buttons to select individual fans or all the fans and
specify whether the server should be shut down after a specified number of
seconds if this fan fails.

Select all

Selects all fans.

Deselect all

All selections are cancelled.

Ê

Select the fans for which you wish to define the behavior in the event of a
fault.