FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 294

294
iRMC
S2/S3
Console Redirection - Redirecting the console
Console Redirection Port
Two serial ports are available:
Serial 1
,
Serial 2
.
I
If console redirection is to be performed via LAN, Serial 1 must be
set.
If
Serial 2
is selected, only the connection over the null modem
cable works.
Serial Port Baud Rate
The following baud rates can be set: 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200.
Serial Port Flow Control
The following settings are possible:
None
Flow control is disabled.
XON/XOFF (Software)
Flow control is handled by the software.
CTS/RTS (Hardware)
Flow control is handled by the hardware.
Terminal Emulation
The following terminal emulations are available:
VT100 7Bit, VT100 8Bit
,
PC-ANSI 7Bit
,
PC-ANSI 8 Bit, VT100+
,
VT-UTF8
Serial 1 Multiplexer
Check the consistency of the multiplexer settings:
–
Serial: System
–
LAN: iRMC S2/S3
Ê
Click
Apply
to activate your settings.