FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 221
iRMC S2/S3
221
Sensors - Check status of the sensors
Entries with Designation "iRMC", "Agent", "BIOS", or "VIOM"
Entries with the
Designation
"iRMC", "Agent", "BIOS", or "VIOM" indicate that the
iRMC S2/S3, the agent, the BIOS, or VIOM has detected an error. It does not
mean that the iRMC S2/S3, the agent, the BIOS, or VIOM itself is defective.
Entries with Designation "HDD" and "HDD
("out-of-band" HDD monitoring)
Entries with the
Designation
"HDD" or "HDD
statuses of Hard Disk Drives (HDD):
–
The entry with
Designation
"HDD" indicates the overall HDD status of the
server by summarizing the statuses of the individual HDDs.
The overall HDD status of the server is read and reported to the iRMC S2/S3
by the ServerView agents and the ServerView RAID Manager.
–
An entry with
Designation
"HDD
of an individual HDD.
I
Please note:
–
This feature is only supported by the iRMC S3.
–
This feature only supported if the managed PRIMERGY server
supports the "agentless HDD monitoring" function (also known as
"out-of-band HDD monitoring").
If these requirements are met, the HDD
HDD is reported directly to the iRMC S3, i.e. without using the
ServerView agents.
Figure 123: Status display for individual HDDs