FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 185

iRMC S2/S3
185
iRMC S2/S3 - Information, firmware and certificates
Update file
File in which the firmware image is stored.
I
The files listed below each allow you to update one component of
the iRMC S2/S3 firmware every time TFTP is started (runtime
firmware and SDR record).
The file
rt_sdr_
is also available for
some PRIMERGY servers / blade servers. This allows you to
update all the components of the iRMC S2/S3 firmware in a single
operation using a TFTP server.
dcod
Updates the runtime firmware.
Updates the SDR record.
Flash Selector
Specify what iRMC firmware is to be updated.
You have the following options:
–
Auto - inactive firmware
The inactive firmware is automatically selected.
–
Low Firmware Image
The low firmware image (firmware image 1) is selected.
–
High Firmware Image
The high firmware image (firmware image 2) is selected.
Ê
Click
Apply
to activate your settings.
Ê
Click
TFTP Test
to test the connection to the TFTP server.
Ê
Click
TFTP Start
to download the file containing the firmware image from the
TFTP server and to start updating the iRMC S2/S3 firmware.