Section "service, Section "service processor - ip – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 339

iRMC S2/S3
339
Service Processor
8.11
Service processor - IP parameters,
identification LED and iRMC S2/S3 reset
The following menu appears if you choose
Service Processor...
from the main
menu:
Figure 208: Remote Manager: Service Processor menu
The submenu contains the following functions:
I
It is recommended that you reboot the server after a
Reset iRMC S2/S3
(Cold Reset)
or
Reset iRMC S2/S3 (Warm Reset)
(see
).
Configure IP Parameters
Configure the IPv4 / IPv6 address settings of the
iRMC S2/S3 in a guided dialog. Please refer to
section "Network Interface Settings - Configure
Ethernet settings on the iRMC S2/S3" on page 239
for details in the individual settings.
List IP Parameters
Display the IP settings.
Toggle Identify LED
Switch the PRIMERGY identification LED on/off.
Reset iRMC S2/S3
(Warm reset)
Reset the iRMC S2/S3. The connection is closed.
Only the interfaces are re-initialized.
Reset iRMC S2/S3
(Cold reset)
Reset the iRMC S2/S3. The connection is closed.
The entire iRMC S2/S3 is re-initialized.
Table 15: Service Processor menu