Scci-compliant power on/off commands – FUJITSU INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 User Manual
Page 388

388
iRMC
S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
12.1.2.2 SCCI-compliant Power On/Off commands
01 15 - Get Power On Source
This command returns the reason for the most recent Power On. The possible
reasons are listed below.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
01
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
15
Command Specifier
Response Data
-
BC
-
01
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
3
01
Data Length
4
Power on Source: Cause of last power on
Power on
Source
Description
0x00
Software or command
0x01
Power switch (on the front panel or keyboard)
0x02
Automatic restart after power failure
0x03
Clock or timer (hardware RTC or software timer)
0x04
Automatic restart after fan failure shutdown
0x05
Automatic restart after critical temperature shutdown
0x08
Reboot after watchdog timeout
0x09
Remote on (modem RI line, SCSI termination power, LAN, chip card
reader...)
0x0C
Reboot after a CPU error
0x15
Reboot by hardware reset
0x16
Reboot after warm start
0x1A
Powered on by a PCI Bus Power Management Event
0x1D
Powered on by remote control via remote manager
0x1E
Reboot/reset by remote control via remote manager