79
Waves eMotion LV1 User Guide |
Chapte
r
3
:
Channel
Window
Window
6–P
REAMP
A
NALOG
G
AIN
Adjusts the analog level of a digitally controlled preamp. Unlinked stereo L/R channels can be controlled separately, as can two
mono inputs from different sources. Knob position is displayed in the value box.
Preamps can also be controlled from their
respective control panels, which are accessed from the System Inventory page. There are two preamp gain control modes: Preamp,
which controls the preamp analog gain, and Local, which delivers the same level from the preamp, regardless of the preamp gain
setting. Refer to the next section of this chapter,
Controlling Preamp Gain on Shared Devices.
7–P
REAMP
P
OLARITY
R
EVERSE
Reverses the polarity of a preamp input channel. Independent left and right controls.
Options: on/off, default: off
8–C
HANNEL
I
NPUT
T
RIM
C
ONTROLS
Controls the channel’s pre-fader digital input level. Independent left and right controls.
Range: -INF to +10 dB
9–I
NPUT
M
ETER
P
EAK
I
NDICATOR
Displays meter peak level. Red indicates that the user-defined clip threshold is exceeded. Click on the meter or value box to clear.
Meter behavior is set at Settings > U/I Settings:
Metering point: pre- or post-digital trim Clip
threshold indicator range: -9 to 0 dBFS
Clip hold and peak hold range: 0 seconds to INF
10–M
ONO
/S
TEREO
M
ETER
Peak input level
Range: -INF to 0 dBFS
11–F
ILTER
S
ECTION
Controls an HP/LP filter that has been assigned in the plugin rack.
Range (eMo F2): 16 Hz to 21357 Hz (values vary depending on plugin)
Refer to Channel window > Main Control Section > Controlling a Filter for more information.