Filter blocks, Index – Biamp LTR User Manual
Page 221

System Control
Center Freq.
PEQFCBND
SET, SETL, GET, GETL, INC,
DEC
1
20 ~ 20000
EQ Band Level
PEQLVLBND
SET, SETL, GET, GETL, INC,
DEC
1
-30 ~ 15 *
Bypass All Bands
PEQBYPALL
SET, GET
None 0 =active
1 = bypassed
* Can contain a decimal number.
Note:
Index1 represents the filter to be controlled. Parametric EQ filters are initially numbered
from left to right, and the selected band is displayed in the upper left hand corner of the
Parametric EQ dialog screen in Audia software. Use this number as Index1 for Parametric EQ
strings.
Example: Increment Device 1 Parametric EQ Band Level at Instance 11 Band 2 by 2dB.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
INC 1
PEQLVLBND
11 2 None
2
Result: INC 1 PEQLVLBND 11 2 2
Feedback Suppressor
Attribute
Commands
Index
Value Range
Reset All Filters
FBSRESET
SET
None None
Fix All Filters
FBFIXALL
SET, GET
None 0 = not fixed
1 = fix all
Example: Set Device 1 Feedback Suppressor Reset All Filters at Instance 4.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 1
FBSRESET 4 None
None None
Result: SET 1 FBSRESET 4
Filter Blocks
HPF
Attribute
Commands
Index
Value Range
201