Biamp LTR User Manual
Page 210
Audia-Manual-LTR
* Can contain a decimal number.
Example: Set Device 1 Input Level at Instance ID 6, Input 3 to –10dB.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET
1
INPLVL 6 3
None -10
Result: SET 1 INPLVL 6 3 –10
AEC Inputs
Attribute
Commands
Index
Value Range
Input Gain
AECMICGAIN
SET, SETL, GET, GETL, INC,
DEC
1
0, 6, 12, 18, 24, 30, 36, 42,
48, 54, 60, 66
Input Level
AECINPLVL
SET, SETL, GET, GETL, INC,
DEC
1
-100 ~ 12 *
Phantom Power
AECPHPWR
SET, GET
1
0 = off
1 = on
Input Mute
AECINPMUTE
SET, GET
1
0 = unmuted
1 = muted
Invert Polarity
AECINPINVRT
SET, GET
1
0 =normal
1 = inverted
Enable AEC
AECENABLE
SET, GET
1
0 = off
1 = on
NLP Strength
AECNLP
SET, GET
1
0 = off
1 = soft
2 = medium
3 = aggressive
Noise Reduction
AECNR
SET, SETL, GET, GETL
1
0, and 6 ~ 15
* Can contain a decimal number.
Example: Set Device 1 AEC NLP Strength at Instance ID 24, Input 3 to aggressive.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
190