Control blocks – Biamp LTR User Manual
Page 228
Audia-Manual-LTR
Delay in Meters
DLYM
SET, SETL, GET, GETL
None 0 ~ block maximum *
Delay in Inches
DLYIN
SET, SETL, GET, GETL
None 0 ~ block maximum *
Delay in Feet
DLYFT
SET, SETL, GET, GETL
None 0 ~ block maximum *
Delay Bypass
DLYBYP
SET, GET
None 0 ~ block maximum *
* Can contain a decimal number.
Note
: Value Range is from 0 to the maximum value for the specific delay block. For example, a
50mSec delay has a maximum setting of 1717 centimeters, 17 meters, 676 inches, or 56 feet.
Example: Set Device 1 Delay In Centimeters at Instance 24 to 40 centimeters.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 1 DLYCM 24 None
None 40
Result: SET 1 DLYCM 24 40
Control Blocks
Level Faders
Attribute
Commands
Index
Value Range
Fader Level
FDRLVL
SET, SETL, GET, GETL, INC,
DEC
1
-100 ~ 12 *
Fader Mute
FDRMUTE
SET, GET
1
0 = unmuted
1 = muted
* Can contain a decimal number.
Mute Button
Attribute
Commands
Index
Value Range
Mute
MBMUTE
SET, GET
1
0 = unmuted
1 = muted
Logic State
Attribute
Commands
Index
Value Range
Logic State
LGSTATE
SET, GET
1
0 = off
1 = on
208