Explanation: The specified group requires so many links to other groups that it
would exceed the
. Normally, the
number of CobraNet connections could be reduced by combining
the specified group with some other group(s). However, in this case,
the number of CobraNet connections cannot be reduced sufficiently.
Message: Could not find a solution.
Explanation: Compile was unable to place the produced groups into available
Audia units. Attempt to use
change the formation of groups..
Message: Although the total DSP power is sufficient, the compiler cannot place
the resulting groups into the Audia units in the Equipment Table.
More units would have to be added.
Explanation: Compile was not able to distribute the produced groups among the
available Audia units. This can only occur if the flag 'Auto Device
Add' is not set under
. Attempt to produce
smaller groups using fixed allocations and/or ganging. If
unsuccessful, set 'Auto Device Add' so Compile will automatically
add necessary Audia units to the
. Audia units can
also be added manually.
Message: Total maximal duration of delays exceeded in the unit #_.
Explanation: The number of delay blocks, and their combined delay ranges,
exceeds the maximum capability of this unit. Currently, any single
Audia unit can provide a maximum of 45 seconds of delay blocks.
Matrix Mixers with Delay also contribute to this total, consuming
1 second per input channel.
Allocation of DSP blocks to DSPs