Meter blocks – Biamp LTR User Manual
Page 229
System Control
Presets
Attribute
Commands
Index
Value Range
Preset PRESET
RECALL
None
1001 ~ maximum number
of presets
Note
: Instead of SET, SETL, GET, GETL, INC, or DEC; the Preset attribute uses RECALL as the
command. Preset numbers begin at 1001. Regardless of preset name, the first preset defined is
1001, the second is 1002, and so forth. However, the numbers of any deleted Presets will not be
available. Since Presets apply to entire systems, the Device Number will always be 0 for Preset
strings.
Example: Recall Device 0 Preset number 1001.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
RECALL 0 PRESET None None None
1001
Result: RECALL 0 PRESET 1001
Meter Blocks
Meters
Attribute
Commands
Index
Value Range
Signal Present Meter
SPMTRSTATE
GET
1
0 = no signal present
1 = signal present
Peak Meter
PKMTRLVL
GET, GETL
1
-100 ~ 36 *
RMS Meter
RMSMTRLVL
GET, GETL
1
-100 ~ 36 *
Logic Meter
LGCMTRSTATE
GET
1
0 = no signal present
1 = signal present
* Can contain a decimal number.
Note:
Meters only use GET and GETL commands, which do not include a Value. Instead, Audia
will respond to these GET/GETL commands with the requested value (current level).
Example: Get Device 1 RMS Meter Level at Instance 48 Meter 1.
209