Audia-Manual-LTR

If an Audia does not have a system loaded into it, you can set the Default Gateway IP Address
via the RS-232 port. Example: "SET 0 DEFAULTGW 192.168.1.1 ". If there is no DAP file in
the Audia, and the command is typed correctly, Audia will send back a +OK response. You will
need to power cycle the Audia for the new default gateway IP Address to take effect. As stated
above, Audia will output the default gateway IP Address when powered up, or you can use the
GET DEFAULTGW command mentioned above.

Get MAC Address

By typing "GET 0 MACADDRESS " in HyperTerminal Audia will reveal the MAC Address of
the Audia’s network interface. Substituting the ‘0’ for a 1, 2, 3, etc will tell Audia to reveal the MAC
Address for the device who's number is 1, 2, 3 etc. A "0" asks for the MAC Address of the Audia
you are currently connected to. Note: You can only use a 1, 2, 3 etc if there is a system loaded
into the Audia's. If it is a single device system, the only device number will be 1.

Reset

In rare instances it may become necessary to reset the Audia device. A reset can be
accomplished through the device maintenance screen, and this is the desired method for a reset.
However, there is a reset command available via the RS-232 port. Simply type: "CLEAR 0
DEVCONFIG
"

and the device will be reset.

CobraNet IP Address

These attributes and resulting commands affect the

Audia CobraNet IP Configuration

.

Use the

default setting (Obtain an IP address automatically) in all cases, except when adding CobraNet to
an existing Ethernet network (not recommended).