Biamp LTR User Manual
Page 215
System Control
Suppresion
1 = on
* Can contain a decimal number.
TI-2 Transmit
Attribute
Commands
Index
Value Range
Transmit Level
TITXLVL
SET, SETL, GET, GETL, INC,
DEC
None -100 ~ 0 *
Transmit Mute
TITXMUTE
SET, GET
None 0 = unmuted
1 = muted
* Can contain a decimal number.
Example: Mute the TI-2 Transmit Block at Instance ID 21
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 1
TITXMUTE 21 None
None
1
Result: SET 1 TITXMUTE 21 1
CobraNet
Input
Attribute
Commands
Index
Value Range
CobraNet
RX Bundle
CNINBNDL SET,
GET
None
1-65279
CobraNet
Input Level
CNINLVL
SET, SETL, GET, GETL, INC,
DEC
1
-100 ~ 12 *
CobraNet
Input Mute
CNINMUTE
SET, GET
1
0 = unmuted
1 = muted
CobraNet
Input Invert
CNININVRT
SET, GET
1
0 = off
1 = on
* Can contain a decimal number.
CobraNet
Attribute
Commands
Index
Value Range
195