Dynamics blocks – Biamp LTR User Manual
Page 225
System Control
Result: GET 2 XOVR3FC 40 1
Dynamics Blocks
Leveler
Attribute
Commands
Index
Value Range
Bypass
LVLRBYP
SET, GET
None 0 = active
1 = bypassed
Comp/Limiter
Attribute
Commands
Index
Value Range
Bypass
CLIMBYP
SET, GET
None 0 = active
1 = bypassed
Ducker
Attribute
Commands
Index
Value Range
Input Level
DKRLVLIN
SET, SETL, GET, GETL
None -100 ~ 12 *
Level Sense
DKRLVLSENSE
SET, SETL, GET, GETL
None -100 ~ 12 *
Bypass Ducker
DKRBYP
SET, GET
None 0 = active
1 = bypassed
Mute Sense
DKRMUTESENSE
SET, GET
None 0 = unmuted
1 = muted
Input Mute DKRMUTEIN
SET,
GET
None
0 = unmuted
1 = muted
Logic In Enable
DKRENLOGIN
SET, GET
None 0 = disabled
1 = enabled
Logic Out Enable
DKRENLOGOUT
SET, GET
None 0 = disabled
1 = enabled
Logic Input Invert
DKRINVLOGIN
SET, GET
None 0 = normal
1 = inverted
Logic Output Invert
DKRINVLOGOUT
SET, GET
None 0 = normal
1 = inverted
* Can contain a decimal number.