Biamp LTR User Manual
Page 216
Audia-Manual-LTR
Output
CobraNet
TX Bundle
CNOUTBNDL SET,
GET
None
1-65279
CobraNet
Output Level
CNOUTLVL
SET, SETL, GET, GETL, INC,
DEC
2
-100 ~ 0 *
CobraNet
Output Mute
CNOUTMUTE
SET, GET
2
0 = unmuted
1 = muted
CobraNet
Output Invert
CNOUTINVRT
SET, GET
2
0 = off
1 = on
* Can contain a decimal number.
EXPI
Attribute
Commands
Index
Value Range
EXPI
RX Bundle
EXPIBNDL SET,
GET
None
1-65279
EXPI
Input Level
EXPILVL
SET, SETL, GET, GETL, INC,
DEC
1
-100 ~ 12 *
EXPI
Input Mute
EXPIMUTE
SET, GET
1
0 = unmuted
1 = muted
EXPI
Input Invert
EXPIINVRT
SET, GET
1
0 = off
1 = on
* Can contain a decimal number.
EXPO
Attribute
Commands
Index
Value Range
EXPO
TX Bundle
EXPOBNDL SET,
GET
None
1-65279
EXPO
Output Level
EXPOLVL
SET, SETL, GET, GETL, INC,
DEC
1
-100 ~ 0 *
EXPO
Output Mute
EXPOMUTE
SET, GET
1
0 = unmuted
1 = muted
EXPO
Output Invert
EXPOINVRT
SET, GET
1
0 = off
1 = on