Message: Could not assign audio I/O channels in the unit # __.

Explanation: Indicates a software problem. Please contact Biamp Systems.

Messages: Available range of Instance IDs is nearly exhausted.

Range of Instance IDs has been exhausted.

Explanation: The total number of

Instance IDs

, as assigned to component and

line objects, is limited to 65,535. When component objects are

removed from a design, their Instance IDs are not automatically

re-assigned to new component objects. Therefore, the messages

above indicate that a significant number of Instance IDs has been

wasted. Set 'Reassign Instance IDs' under

Tools>Options>Compile

and re-compile to recover wasted Instance IDs. CAUTION: This

will change most component Instance IDs, and will render existing

external control command scripts useless (unless Instance ID Tags

have been used in lieu of Instance ID numbers).

Once Instance IDs

have been recovered, turn off 'Reassign Instance IDs' to avoid

further re-assignments.

Message: I/O channel assignment in the unit # __ is inconsistent with factory

hardware configuration.

Explanation:

AudiaFLEX

units leave the factory with I/O cards arranged in specific

order, with input cards starting on the right (when viewing the rear panel),

and output cards starting on the left. If the Compiler encounters an I/O

channel number assignment fixed to a unit (through fixed allocation of the

I/O DSP block), which is inconsistent with the factory numbering scheme,

this warning will be given.