beautypg.com

Biamp LTR User Manual

Page 183

background image

System Design

Message: Allocating blocks to DSPs...failed to set up a feasible DSP task

schedule in the unit #__.

Explanation: Although the total DSP power in the Audia unit is sufficient, compile

was not able to distribute the component objects among the

available DSPs. When the DSP load approaches 100%, it becomes

crucial that the objects be distributed more uniformly. Try moving

certain objects to another unit (using

fixed allocations

), or replace

them with a comparable set of smaller objects (within the same unit).

Otherwise, it may be necessary to add an additional Audia unit to the

system, and move large DSP blocks into it using fixed allocations.

Assigning control blocks to Audia units

Message: Some unconnected control blocks have been ignored.

Explanation: Control blocks with no connections have been excluded from the

system. Only

Logic Gate

,

Logic Delay

, and

Remote Preset Button

blocks can be ignored. When connected to the system, control dialogs

for ignored blocks cannot be accessed.

Message: Feedback detected in the control network.

Explanation: The potential exists for a control path to be indirectly looped back

upon itself. This condition could be dangerous, and is not allowed.

Message: Unit #__ has too many control connections.

Explanation: Although quite large, there is a limit to the quantity of control

connections within a single unit. Connections include both internal

(source and destination within same unit) and external links (source

or destination within this unit). Try moving certain control objects to

another unit (using

fixed allocations

),

Setting up the Audia units after a successful compilation