Equalizer blocks, Cobranet ip address – Biamp LTR User Manual
Page 220
Audia-Manual-LTR
Result: SET 1 RMCMBWALL 4 2 1
Mix-Minus Combiner
Attribute
Commands
Index
Value Range
Group State
MCMBGROUP
SET, GET
1
0 ~ 32
Note
: Index1 is the input being addressed. Value is the group; this is represented by a letter in
Audia software, but addressed as a number in ATP commands. (Example: ungroup=0, A=1, B=2,
C=3….)
Equalizer Blocks
Graphic EQ
Attribute
Commands
Index
Value Range
EQ Band Level
GEQLVLBND
SET, SETL, GET, GETL, INC,
DEC
1
-30 ~ 15 *
Bypass All Bands
GEQBYPALL
SET, GET
None 0 = active
1 = bypassed
* Can contain a decimal number.
Note:
Index1 represents the filter to be controlled. Graphic EQ filters are numbered from left to
right, and the selected band is displayed in the upper left hand corner of the Graphic EQ dialog
screen in Audia software. Use this number as Index1 for Graphic EQ strings.
Example: Set Device 2 Graphic EQ Bypass All Bands at Instance 9 to bypass.
Command
Dev #
Attribute
Inst ID
Index 1
Index 2
Value
Line Feed
SET 2
GEQBYPALL 9 None
None
1
Result: SET 2 GEQBYPALL 9 1
Parametric EQ
Attribute
Commands
Index
Value Range
EQ Bandwidth
PEQBWBND
SET, SETL, GET, GETL
1
0.010 ~ 4.000 *
Bypass EQ Band
PEQBYPBND
SET, GET
1
0 = active
1 = bypassed