beautypg.com

All-pass filter, Crossovers, Leveler – Biamp LTR User Manual

Page 135: Comp/limiter, See all-pa

background image

Component Objects

All-Pass Filter

All-Pass Filters are so named because they do not affect frequency response. Instead, they
affect signal phase only and, therefore, can be used to compensate for the phase anomalies
caused by normal equalization filters. All-Pass Filters are available with up to sixteen bands.

Active Band

selects the current band to be adjusted. Center Freq. adjusts the center frequency

for the current band.

Bandwidth

adjusts the range of frequencies, above & below the center

frequency, which are also affected by the current band. These settings may also be adjusted by
dragging the band controls shown inside the graph. Dragging the white dot affects Center Freq.
Dragging either yellow dot affects Bandwidth. Add Band & Remove Band work within the
designated number of bands for the filter. Bypass Band & Bypass All disable the band(s)
without changing settings. Drag Points turns on/off the band controls, revealing the resultant
curve only. Band highlights the phase response of the current band inside the graph.

See

Transfer Function

as an effective diagnostic tool to be used in conjunction with All-Pass

Filters.

Right-clicking over certain settings will provide a menu of additional options.

Crossovers

Crossovers

These Component Objects provide 2-way, 3-way, & 4-way crossover functions. Crossovers may
be connected between any components within the Layout, for applications which require
multiple outputs with specified frequency ranges.

115