All-pass filter, Crossovers, Leveler – Biamp LTR User Manual
Page 135: Comp/limiter, See all-pa
Component Objects
All-Pass Filter
All-Pass Filters are so named because they do not affect frequency response. Instead, they
affect signal phase only and, therefore, can be used to compensate for the phase anomalies
caused by normal equalization filters. All-Pass Filters are available with up to sixteen bands.
Active Band
selects the current band to be adjusted. Center Freq. adjusts the center frequency
for the current band.
Bandwidth
adjusts the range of frequencies, above & below the center
frequency, which are also affected by the current band. These settings may also be adjusted by
dragging the band controls shown inside the graph. Dragging the white dot affects Center Freq.
Dragging either yellow dot affects Bandwidth. Add Band & Remove Band work within the
designated number of bands for the filter. Bypass Band & Bypass All disable the band(s)
without changing settings. Drag Points turns on/off the band controls, revealing the resultant
curve only. Band highlights the phase response of the current band inside the graph.
See
as an effective diagnostic tool to be used in conjunction with All-Pass
Filters.
Right-clicking over certain settings will provide a menu of additional options.
Crossovers
Crossovers
These Component Objects provide 2-way, 3-way, & 4-way crossover functions. Crossovers may
be connected between any components within the Layout, for applications which require
multiple outputs with specified frequency ranges.
115