ProSoft Technology PTQ-PDPMV1 User Manual
Page 168

Mailbox Messaging
PTQ-PDPMV1 ♦ Quantum Platform
User Manual
PROFIBUS DP Master Network Interface Module for Quantum
Page 168 of 306
ProSoft Technology, Inc.
August 12, 2014
Data [1 … n]
Returned data.
Fault Information and Extended Fault Information
If "Invalid Other" is returned in the Message Information word in the header of the
response, information about the fault can be found here.
Fault Information
Extended Fault Information Contents
0100h
Address out of range
-
0A00h
Failed to execute request
Refer to Return Codes (page 181).
0B00h
Remote station failure
1000h
Remote station DPV1 failure
Function_Number
1100h
Length out of range (>240 bytes)
-
1200h
Slave does not support DPV1
-
1300h
Slave not active or not present in
configuration
-
FE00h
Command not possible in "Class 2-Only"
mode
-
FF00h
Module offline (not initialized or no valid
database)
-
Error Decode, Error Code 1 and Error Code 2
If "Fault Information" contains error code 1000h, more information according to
the DPV1 specification can be found here.
6.2.7 Mailbox Message: Acyclic Data Write: Class 1
This command initiates a DPV1 Class 1 acyclic write request. Refer to EN50170
(DPV1) for more information.
Parameter
Description
Command Initiator
Application
Command Name
MSAC1 WRITE
Command Number
2100h
Fragmented
No
Extended Header Data
Fault information may be returned in the header of the response.