Setting User Constants

4.2.3 User Constant Access Levels

- 10

Setting a User Constant in the Advanced Access Level

The group level will be displayed when the DATA/ENTER Key is pressed at the programming mode dis-
play.
Use the following procedure to set a constant.

Step

Key Sequence

Digital Operator Display

Remarks

1

MENU

MC5

Main Menu

Operation

2

Press twice.

MC5

Main Menu

Programming

3

DATA

ENTER

Group b

Application

4

Group C

Tuning

5

DATA

ENTER

Function C1
Accel/Decel

Changed to constant reading (function)
level.

6

DATA

ENTER

Accel Time 1

C1

--

01 = 10

.

0 Sec

7

DATA

ENTER

Accel Time 1

0010

.

0 Sec

Selects the user constant so that the
leading 0 blinks. The blinking digit
can be changed.

8

RESET

Press twice.

Accel Time 1

0010

.

0 Sec

Blinking digit moves 2 places to the
right and the “1” blinks.

9

Accel Time 1

0020

.

0 Sec

Changes 1 to 2.

10

DATA

ENTER

Entry Accepted

Writes-in the new setting, 20.0 s.

Accel Time 1

C1

--

01 = 20

.

0 Sec

After a few seconds, the Operator dis-
play is as shown on the left.

11

ESC

Function C1
Accel/Decel

The constant setting in Advanced level (acceleration time change from 10.0 to 20.0 s) has been completed.

4

A