7.3

Common Functions

- 45

Analog Input Characteristics

D

Analog input characteristics for a gain of 100.0% and a bias of 0.0% are shown for setting examples
in Table 7.9.

D

To set over 100% for a 10 V input (e.g., 300%/10 V), set the gain to 300% in H3-06 for terminal 16
and H3-10 for terminal 14.

Table

7.9

Analog Input Characteristics

S Auxiliary Frequency Reference (Setting: 0)
S Frequency Bias (Setting: 2)
S PID Feedback (Setting: B)
S Frequency reference (H3-09 setting: 1F)

S Frequency Gain (Setting: 1)
S Output Voltage Bias (Setting: 4)
S DC Injection Braking Current (Setting: 6)

S Acceleration/Deceleration Time Gain (Set-

ting: 5)

--

10 V

0

10 V

100 %

--100 %

When set to 1, the setting of H3-02 will be
added to achieve the final gain.

--

10 V

0

10 V

100 %

1 V

--

10 V

0

10 V

100 %

10 %

S DC Injection Braking Current (Setting: 6)
S Overtorque Detection Level (Setting: 7)

S Stall Prevention Level (Setting: 8)

S Output Frequency Lower Limit (Setting: 9)
S Jump Frequency (Setting: A)

Only the overtorque detection 1 output can be
used when “7” is set to use overtorque detec-
tion for a multi-function output.

--

10 V

0

10 V

100 %

3 V

--

10 V

0

10 V

100 %

30 %

--

10 V

0

10 V

100 %

S Torque Reference (Setting: 13)
S Torque Compensation Bias (Setting: 14)

S Forward Torque Limit (Setting: 10)
S Reverse Torque Limit (Setting: 11)
S Regenerative Torque Limit (Setting: 12)

S Forward/Reverse Torque (Speed) Limit (Set-

ting: 15)

--

10 V

0

10 V

100 %

--100 %

--

10 V

0

10 V

100 %

0

10 V

100 %

--100 %

7