Yaskawa VS-626 MC5 User Manual
Page 286
12.5
User Constants
- 17
Table 12.1
User Constants (Continued)
No.
Name
(Display)
Factory
Setting
Setting
No.
Name
(Display)
Factory
Setting
Setting
E4-05
Motor 2 mid. output frequency voltage 1
1
(V/F2 Mid Voltage)
11.0
2
F5-02
Channel 2 output selection
(DO-02 Ch2 Select)
1
E4-06
Motor 2 min. output frequency
(V/F2 Min Freq)
0.5
F6-01
Output mode selection
(DO-08 Selection)
0
E4-07
Motor 2 min. output frequency voltage
1
(V/F2 Min Voltage)
2.0
2
F7-01
Frequency multiple selection
(PO-36F Selection)
1
E5-01
Motor 2 rated current
1
(Motor 2 rated FLA)
1.9
3
F8-01
Transmission option (SI-F/G)
1
(E-15 Det Sel)
1
E5-02
Motor 2 rated slip
1
(Motor 2 Slip Freq)
2.90
3
F9-01
External fault input level from transmissin op-
tion (FF0 Selection)
1
0
E5-03
Motor 2 no-load current
1
(Motor 2 No-load I)
1.20
3
F9-02
External fault detection from transmission op-
tion (EF0 Detection)
1
0
E5-04
Motor 2 number of poles
1
(Motor 2 # Poles)
4 poles
F9-03
Action for external fault from transmission op-
tion (EF0 Fault Act)
1
1
E5-05
Motor 2 line-to-line resistance
1
(Motor 2 term Ohms)
9.842
3
F9-04
Transmission option trace sampling time
(Trace Sample Time)
1
0
E5-06
Motor 2 leak inductance
1
(Motor 2 Leak)
18.2
3
H1-01
Multi-function input (terminal 3)
(Terminal 3 Sel)
24
F1-01
PG constant
(PG Pulse/Rev)
600
H1-02
Multi-function input (terminal 4)
(Terminal 4 Sel)
14
F1-02
Operation selection at PG open circuit
(PG Fdbk Loss Sel)
1
H1-03
Multi-function input (terminal 5)
(Terminal 5 Sel)
3 (0)
5
F1-03
Operation selection at overspeed
(PG Overspeed Sel)
1
H1-04
Multi-function input (terminal 6)
(Terminal 6 Sel)
4 (3)
5
F1-04
Operation selection at deviation
(PG Deviation Sel)
3
H1-05
Multi-function input (terminal 7)
(Terminal 7 Sel)
6 (4)
5
F1-05
PG rotation
(PG Rotation Sel)
0
H1-06
Multi-function input (terminal 8)
(Terminal 8 Sel)
8 (6)
5
F1-06
PG division rate (PG pulse monitor)
(PG output Ratio)
1
H2-01
Multi-function input (terminal 9-10)
(Terminal 9 Sel)
0
F1-07
Integral value during accel/decel enable/dis-
able
(PG Ramp PI/I Sel)
0
H2-02
Multi-function input (terminal 25-27)
(Terminal 25 Sel)
1
F1-08
Overspeed detection level
(PG Overspd Level)
115
H2-03
Multi-function input (terminal 26-27)
(Terminal 26 Sel)
2
F1-09
Overspeed detection delay time
(PG Overspd Time)
0.0
4
H3-01
Signal level selection (terminal 13)
(Term 13 Signal)
0
F1-10
Excessive speed deviation detection level
(PG Deviate level)
10
H3-02
Gain (terminal 13)
(Terminal 13 Gain)
100.0
F1-11
Excessive speed deviation detection delay time
(PG Deviate Time)
0.5
H3-03
Bias (terminal 13)
(Terminal 13 Bias)
0.0
F1-12
Number of PG gear teeth 1
(PG# Gear Teeth 1)
0
H3-04
Signal level selection (terminal 16)
(Term 16 Signal)
0
F1-13
Number of PG gear teeth 2
(PG# Gear Teeth 2)
0
H3-05
Multi-function analog input (terminal 16)
(Terminal 16 Sel)
0
F1-14
PG open-circuit detection time
1
(PGO Time)
2.0
H3-06
Gain (terminal 16)
(Terminal 16 Gain)
100.0
F2-01
Bi-polar or uni-polar input selection
(AI-14 Input Sel)
0
H3-07
Bias (terminal 16)
(Terminal 16 Bias)
0.0
F3-01
Digital input option
(DI Input)
0
H3-08
Signal level selection (terminal 14)
(Term 14 Signal)
2
F4-01
Channel 1 monitor selection
(AO Ch1 Select)
2
H3-09
Multi-function analog input (terminal 14)
(Terminal 14 Sel)
1F
F4-02
Channel I gain
(AO Ch1 Gain)
1.00
H3-10
Gain (terminal 14)
(Terminal 14 Gain)
100.0
F4--03
Channel 2 monitor selection
(AO Ch2 Select)
3
H3-11
Bias (terminal 14)
(Terminal 14 Bias)
0.0
F4-04
Channel 2 gain
(AO Ch2 Gain)
0.50
H3-12
Analog input filter time constant
(Filter Avg Time)
0.00
F4--05
Channel 1 output monitor bias
(AO Ch1 Bias)
0.0
H4-01
Monitor selection (terminal 21)
(Terminal 21 Sel)
5
F4--06
Channel 2 output monitor bias
(AO Ch2 Bias)
0.0
H4-02
Gain (terminal 21)
(Terminal 21 Gain)
1.00
F5-01
Channel 1 output selection
(DO-02 Ch1 Select)
0
H4-03
Bias (terminal 21)
(Terminal 21 Bias)
0.0
* 1. Not displayed for some models depending on software version No.
* 2. Setting for 200 V class Inverters. For 400 V class Inverters, double the value.
* 3. Setting unit and initial setting depend on Inverter capacity.
* 4. Depends on the control method (A1-02).
* 5. Factory setting in the parentheses is for 3-wire sequence.
12