Yaskawa VS-626 MC5 User Manual
Page 236
User Constants
8.2.7 Protection Constants: L
- 28
J
Fault Restart: L5
Constant
Name
Setting
Factory
Change
during
Control Methods
Constant
Number
Display
Description
Setting
Range
Factory
Setting
g
during
Opera-
tion
Open Loop
Vector
Flux Vector
Page
L5-01
Number of auto re-
start attempts
Sets the number of auto restart at-
tempts.
Automatically restarts after a fault
0 to 10
0
B
B
- 56
L5 01
Num of Restarts
Automatically restarts after a fault
and conducts a speed search from
the run frequency.
0 to 10
0
B
B
- 56
L5-02
Auto restart operation
selection
Sets whether a fault contact output
is activated during fault restart.
0: Not output (Fault contact is not
activated )
0 1
0
B
B
- 56
L5 02
Restart Sel
activated.)
1: Output (Fault contact is acti-
vated.)
0 1
0
B
B
- 56
J
Torque Detection: L6
Constant
Name
Setting
Factory
Change
during
Control Methods
Constant
Number
Display
Description
Setting
Range
Factory
Setting
g
during
Opera-
tion
Open Loop
Vector
Flux Vector
Page
L6-01
Torque detection
selection 1
0: Overtorque detection disabled.
1: Detection during speed agree
only/Operation continues after
detection (Minor fault)
2: Detection during run/Operation
continues after detection (Minor
fault)
0 to 4
0
B
B
- 56
L6 01
Torq Det 1 Sel
fault)
3: Detection during speed agree
only/Inverter output is shut off
after detection (Fault)
4: Detection during run/Inverter
output is shut off after detection
(Fault)
0 to 4
0
B
B
- 56
L6-02
Torque detection level
1
Vector control: Motor rated torque
is set as 100%
0 to 300
150
B
B
- 56
L6 02
Torq Det 1 Lvl
is set as 100%.
0 to 300
150
B
B
- 56
L6-03
Torque detection time
1
Sets the torque detection time in
1-second units
0.0 to
10 0
0.1
B
B
- 56
L6 03
Torq Det 1 Time
1-second units.
10.0
0.1
B
B
- 56
L6-04
Torque detection
selection 2
Setting procedure is the same as for
“Torque detection selection 1”
0 to 4
0
A
A
- 56
L6 04
Torq Det 2 Sel
“Torque detection selection 1”
(L6-01 to L6-03.)
0 to 4
0
A
A
- 56
L6-05
Torque detection level
2
(
)
The following outputs are possible:
Torque detection selection 1:
Multi function output “Torque
0 to 300
150
A
A
- 56
L6 05
Torq Det 2 Lvl
Multi-function output “Torque
detection selection 1” NO/NC
0 to 300
150
A
A
- 56
L6-06
Torque detection time
2
detection selection 1 NO/NC
Torque detection selection 2:
Multi-function output “Torque
detection selection 2” NO/NC
0.0 to
10 0
0.1
A
A
- 56
L6 06
Torq Det 2 Time
detection selection 2” NO/NC
10.0
0.1
A
A
56
8