User Constants

8.2.11 Factory Settings that Change with the Inverter Capacity (o2-04)

- 36

J

400 V Class Inverters

Con-
stant

No.

Name

Unit

Factory Setting

Inverter Capacity

kW

0.4

0.75

1.5

2.2

3.7

4.0

5.5

7.5

11

o2-04

kVA selection

1

20

21

22

23

24

25

26

27

28

C6-01

Carrier frequency upper limit *

kHz

15.0

15.0

15.0

15.0

15.0

15.0

15.0

12.5

12.5

Carrier frequency upper limit
range

kHz

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

E2-01

(E5-01)

Motor rated current

A

1.00

1.60

3.10

4.20

7.00

7.00

9.80

13.30

19.9

E2-02

(E5-02)

Motor rated slip

Hz

2.90

2.60

2.50

3.00

2.70

2.70

1.50

1.30

1.70

E2-03

(E5-03)

Motor no-load current

A

0.60

0.80

1.40

1.50

2.30

2.30

2.60

4.00

5.6

E2-05

(E5-05)

Motor line-to-line resistance

38.198

22.459

10.100

6.495

3.333

3.333

1.595

1.152

0.922

E2-06

(E5-06)

Motor leak inductance

%

18.2

14.3

18.3

18.7

19.3

19.3

18.2

15.5

19.6

L2-02

Momentary power loss ridethru
time

sec

1.0

1.0

1.0

1.0

2.0

2.0

2.0

2.0

2.0

L2-03

Min. baseblock time

sec

0.5

0.5

0.5

0.5

0.5

0.7

0.7

0.7

0.7

L2-04

Voltage recovery time

sec

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

Con-
stant

No.

Name

Unit

Factory Setting

Inverter Capacity

kW

15

18.5

22

30

37

45

55

75

o2-04

kVA selection

1

29

2A

2B

2C

2D

2E

2F

30

C6-01

Carrier frequency upper limit

kHz

12.5

12.5

10.0

10.0

10.0

7.0

6.0

6.0

Carrier frequency upper limit
range

kHz

15.0

15.0

15.0

15.0

10.0

10.0

10.0

10.0

E2-01

(E5-01)

Motor rated current

A

26.5

32.9

38.6

52.3

65.6

79.7

95.0

130.0

E2-02

(E5-02)

Motor rated slip

Hz

1.60

1.67

1.70

1.80

1.33

1.60

1.46

1.39

E2-03

(E5-03)

Motor no-load current

A

7.6

7.8

9.2

10.9

19.1

22.0

24.0

36.0

E2-05

(E5-05)

Motor line-to-line resistance

0.550

0.403

0.316

0.269

0.155

0.122

0.088

0.092

E2-06

(E5-06)

Motor leak inductance

%

17.2

20.1

23.5

20.7

18.8

19.9

20.0

20.0

L2-02

Momentary power loss ridethru
time

sec

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

L2-03

Min. baseblock time

sec

0.7

1.0

1.0

1.0

1.0

1.0

1.0

1.0

L2-04

Voltage recovery time

sec

0.3

0.6

0.6

0.6

0.6

0.6

0.6

0.6

*

When frequency upper limit is set higher than the factory setting with the inverter of 7.5kW or more, inverter rated current should

be reduced. Contact your YASKAWArepresentative for details.

8