Hex Code
Description
ErrorClass
AxisErrorID
ErrorClass+AxisErrorID output from
MC_ReadAxisError
AlarmID
AlarmID output from Y_ReadAlarm
controller's web interface.
app
340C
0126
Internal PLC Error: Error during indirect variable
access.
app
340C
0127
PLC CPU overload.
app
340C
0128
Internal PLC Error: Breakpoint unexpected.
app
340C
0129
Internal PLC Error: Error in data configuration.
app
340C
012A
Internal PLC Error: Error in retain data configuration.
app
340C
012B
Internal PLC Error: Floating point error.
app
340C
012C
Internal PLC Error: Fatal error.
app
340C
012D
Output string is too short.
app
340C
012E
Input string is too short.
app
340C
012F
Invalid input parameter 'p' or 'l' (position or length).
app
340C
0130
String is identical to the output string.
app
340C
0131
Invalid string comparison.
app
340C
0132
Invalid data type for string conversion.
app
340C
0133
Error in format string.
app
340C
0134
Error during string conversion.
app
340C
0135
Error in I/O configuration.
app
340C
0136
Initializing I/O driver failed.
app
340C
0137
Board not instantiated.
app
340C
0138
Board number not allowed.
app
340C
0139
Input Group doesn't fit.
app
340C
013A
Output Group doesn't fit.
app
340C
013B
Board not found.
app
340C
013C
Error reading inputs.
app
340C
013D
Error writing outputs.
app
340C
013E
Error creating I/O semaphore.
app
340C
013F
Invalid memory size.
app
340C
0140
Invalid I/O memory address.
app
340C
0141
Internal PLC Error: PG defined more than once.
app
340C
0142
POU exceeds 64K module size during insertion. POU
size must be reduced.
app
340C
0143