Controller alarmid list – Yaskawa MotionWorks IEC Hardware User Manual
Page 127

MotionWorks IEC Hardware Configuration – 2013-03-26
124
Controller AlarmID List
The following is a list of alarm codes that are reported in the Hardware
Configuration's Alarms tab or via the Y_ReadAlarm function block. These
are non axis specific system alarms.
Hex Code
Description
ErrorClass
AxisErrorID
ErrorClass+AxisErrorID output from
MC_ReadAxisError
AlarmID
AlarmID output from Y_ReadAlarm
motionKernel
1201
0103
An alarm task queue was full when a new alarm was
posted. This indicates that the task is being starved of
execution time or that the system is generating many
alarms simultaneously.
app
1401
0005
The script environment ran out of memory. This is a
serious condition because it may prevent further errors
from being handled correctly.
app
1401
0006
An error occurred while running the standard error
handler for a general script error. This is a serious
condition because it indicates the standard error
handler is malfunctioning.
app
1401
0007
This error should never occur and is included only for
completeness. It indicates that an unknown and
potentially fatal problem has occurred within the script
engine.
app
1401
000A
The script task failed to stop cleanly, which may result
in unreleased system resources. Error recovery
requires the controller be reset.
app
1401
000B
The command line task failed to stop cleanly, which
may result in unreleased system resources. Error