Yaskawa MotionWorks IEC Hardware User Manual
Page 130

MotionWorks IEC Hardware Configuration – 2013-03-26
127
Hex Code
Description
ErrorClass
AxisErrorID
ErrorClass+AxisErrorID output from
MC_ReadAxisError
AlarmID
AlarmID output from Y_ReadAlarm
Mechatrolink
2301
000F
Bus reset generation that controller is not demanding.
Mechatrolink
2301
0010
It receives response with the same channel at the
same Iso cycle.
Mechatrolink
2301
0011
The ID in the response packet is not same to ID of
AxisNode.
Mechatrolink
2301
0012
The data length in the response packet is not same to
value of CSR register(SEND_DSP_DATA_LENGTH) of
drive.
Mechatrolink
2301
0013
The packet type in the response packet is not same S-
DSP.
Mechatrolink
2301
0014
Invalid cycle time has passed with configuration file
'servonet.xml'. As a result, all servo network
communication has been suspended.
Mechatrolink
2301
0015
Node is not found on 1394 network.
Mechatrolink
2301
0016
Invalid node.
Mechatrolink
2301
0017
Error matching node IDs.
DPRAM
2309
0001
Invalid watch dog code from drive
DPRAM
2309
0002
Aux command confirmation failure
DPRAM
2309
0003
Auto configuration failed
DPRAM
2309
0004
Overriding auto configuration failed
DPRAM
2309
0005
Invalid cyclic check sum from drive
DPRAM
2309
0006
Invalid watch dog from drive
DPRAM
2309
0007
Control mode is not supported
DPRAM
2309
0008
Communication with a node failed during servo network
startup
motionKernel
3103
0100
Controller SRAM battery is low
motionKernel
3103
0101
The file system failed the integral consistency
check. Remedy: Power up the controller in
supervisory mode using the SUP switch. Clear the
alarm. Turn off the SUP switch. Power cycle the
controller.
motionKernel
3201
0001
The motion kernel didn't request to enable axis. But,
the axis is enabled.
motionKernel
3201
0002
The motion kernel didn't request to disable axis. But,
the axis is disabled.
motionKernel
3201
0004
The encoder position stored in SRAM could not be