Yaskawa MotionWorks IEC Hardware User Manual
Page 142

MotionWorks IEC Hardware Configuration – 2013-03-26
139
Hex Code
Description
ErrorClass
AxisErrorID
ErrorClass+AxisErrorID output from
MC_ReadAxisError
AlarmID
AlarmID output from Y_ReadAlarm
communication
3403
0304
Modbus TCP network unreachable. Unable to reach the
network for the Modbus TCP slave. Common causes
include: invalid Modbus TCP slave address, invalid
gateway, invalid subnet mask, or the Ethernet network
is not correctly configured.
communication
3403
0305
Modbus TCP slave connection refused. Modbus TCP
slave rejected connection attempt. The Modbus TCP
slave may not be listening for connections or there may
be a firewall preventing the connection.
communication
3403
0306
app
3406
0001
A web server login user was assigned to a group which
did not exist. The system is unaffected, but that user
will have limited (default) access.
app
3406
0002
The default login group for the web server was
assigned to a group which did not exist. Access control
has been disabled, because a minimal amount of
access is required in order to log in. The configuration
file should be fixed before continuing.
app
3406
0003
The web server configuration specified access control
should be enabled, but did not specify at least one path
to control access to. Access control has been disabled.
The configuration file should be fixed before continuing.
app
3407
0002
The base directory for configuration files was missing
and has been created automatically. The system has
booted in a minimal configuration mode, and most
functionality is limited. Please upload a new complete
configuration file set.
app
3407
0003
A required default configuration file was missing. A
minimal configuration for the corresponding component
has been loaded, and some functionality may be
limited.
app
3407
0004
A required default configuration file was incorrectly
formatted. A minimal configuration for the
corresponding component has been loaded, and some
functionality may be disabled.
app
3407
0005
A configuration file specified by the user configuration
file set was incorrectly formatted. The corresponding
default configuration file is being used instead.