Yaskawa MotionWorks IEC Hardware User Manual
Page 146

MotionWorks IEC Hardware Configuration – 2013-03-26
143
Hex Code
Description
ErrorClass
AxisErrorID
ErrorClass+AxisErrorID output from
MC_ReadAxisError
AlarmID
AlarmID output from Y_ReadAlarm
element to the analog I/O element.
app
340A
0020
One or more axes failed to respond to a servo-off
command during a system I/O initiated abort. This is
normally the result of communication problems with
the drive, which also causes an automatic servo-off.
app
340A
0022
Reset of a servo node failed.
app
340A
0023
The axis position may not be valid because the
persistent axis data was corrupted. SRAM should be
reinitialized and the axis should be homed.
app
340C
0000
All PLCopen error codes are in the range from 0x0000
to 0x0fff.
app
340C
0001
Time limit exceeded.
app
340C
0002
Distance limit exceeded.
app
340C
0003
Torque limit exceeded.
app
340C
0100
Modbus TCP I/O Driver Error on Server because of
invalid address range
app
340C
0101
MBTCP Client I/O driver, MBTCP Connection config is
missing input member
app
340C
0102
I/O memory area is not aligned to the correct byte to
accommodate reading and writing.
app
340C
0103
Watchdog Error
app
340C
0104
Reserved
app
340C
0106
Reserved
app
340C
0107
Reserved
app
340C
0108
Reserved
app
340C
0109
Reserved
app
340C
010A
Not enough memory on PLC for POU during insertion.
Project size must be reduced.
app
340C
010B
Internal PLC Error in memory management. This error
can occur if an older project was loaded on the
controller which was compiled to use lees of the
controllers total memory space. By using the
"Resource" Dialog box, perform "Delete On target," for
the bootproject, and then download the application
code again.
app
340C
010C
Internal PLC Error: POU invalid