MotionWorks IEC Hardware Configuration – 2013-03-26

126

Hex Code

Description

ErrorClass

AxisErrorID

ErrorClass+AxisErrorID output from

MC_ReadAxisError

AlarmID

AlarmID output from Y_ReadAlarm

I/O configuration can be matched to the abort inputs
(restart required).

app

140A

0021

Too many events were posted from the system ISR.
The motion scan and servo net loop have been shut
down.

app

140B

0002

The controller ran out of free memory, possibly
resulting in an unrecoverable failure. Please reboot the
controller.

app

140B

0004

The largest free memory block is too small, possibly
resulting in an unrecoverable failure. Please reboot the
controller.

app

140C

1035

The manufacturing data on the controller is invalid. The
controller needs to be returned to Yaskawa for
reprogramming.

Mechatrolink

2301

0001

The drive returned an invalid watch dog code indicating
a possible dropped communication packet.

Mechatrolink

2301

0002

The drive failed to return confirmation of last aux
command within the default timeout period.

Mechatrolink

2301

0003

An unrecoverable error occurred during auto
configuration. As a result, one or more drives are
excluded from the servo network.

Mechatrolink

2301

0004

Overriding the auto configured axes parameters failed.
As a result, one or more drives are excluded from the
servo network.

Mechatrolink

2301

0005

Two or more nodes have the same ID. As a result, all
servo network communication has been suspended.

Mechatrolink

2301

0006

The controller must be the root node on the servo
network. All servo network communication has been
suspended

Mechatrolink

2301

0007

The servo network communication device failed to
initialize. Servo network communication is not possible.

Mechatrolink

2301

0008

An error occurred sending command to a node during
initialization. The node may not support the configured
communications rate. Communication with this node
has been prohibited, but communication with other
nodes may be possible.

Mechatrolink

2301

000E

The drive does not return response packet.