beautypg.com

Video processor frame traps – Grass Valley Karrera Video Production Center Installation v.4.1 User Manual

Page 271

background image

KARRERA — Installation & Service Manual

271

SNMP Monitoring

Video Processor Frame Traps

Table 17. Supported Kayenne/Karrera Frame SNMP Traps

Name

Type

Description

Severity

vsmPowerSupplyStatusChange

status

If the current status is different than the last
status then a trap is sent. A power supply OK
message is only sent if all power supplies are
OK after one of more power supplies have
failed or been removed. At boot time, the first
running status generates an informational
message. After that, a transition to the running
status generates a normal message.

comm error = alarm
fault = alarm
power supply removed = warning
power supply OK = normal

vsmFanStatusChange

status

If the fan board is not present or if all fans have
stopped working a trap is sent. This trap is
resent every 12 seconds until the condition is
corrected.

If any of the fans are not working properly a
trap is sent. This trap is resent every 20 sec-
onds until the condition is corrected.

When the system starts running normally or
returns from an abnormal condition to running
normally a trap is sent.

fan board not present = alarm
all fans not working = alarm
fan not working = warning

normal operation = informational (start up),
normal (returning from a warning or alarm condition)

vsmTempStatusChange

status

If temperature crosses the warm threshold in
any direction a trap is sent.

hot = alarm
normal = normal

vsmModuleStatusChange

powerOK

If the current power status is different than the
last power status a trap is sent.

power OK = normal
power Fault = alarm

vsmModuleStatusChange

status

If the current status is different than the last
status a trap is sent.

operational = normal
failed = alarm
not inserted = warning

vsmReferenceStatusChange

status

When the video reference transitions between
locked and not locked in either direction a trap
is sent.

not locked = warning
locked = normal

gvgElStateChange

status

When the switcher starts the boot process and
the trap status is “initializing” a trap is sent.

Another trap is sent when the switcher
becomes fully operational and the trap status
is “running”.

initializing = warning
running = normal