KARRERA — Installation & Service Manual

Section 7 — Maintenance

Figure 211. Touchscreen Calibration Final Confirmation Screen

9.

Touch the screen to verify the calibration. A calibration circle will
appear and follow your finger touch across the screen. If satisfied,
touch the

Accept

button at the bottom of the screen to save the

calibration.

10.

The Calibration Menu screen then reappears (

Figure 209 on page 257

).

Touch

OK

at the bottom of the screen to exit the application.

Diagnostics

Capture Software Diagnostic Data

Software diagnostic data can be captured on a Karrera Video Processor
Frame. This information can be useful to Grass Valley engineers for trou-
bleshooting purposes. Typically this procedure is only used when the
Karrera system is experiencing problems, and is done after a Video Pro-
cessor Frame reboot.