beautypg.com

H3C Technologies H3C S5120 Series Switches User Manual

Page 89

background image

1-8

To do…

Use the command…

Remarks

Specify to send trap messages
when the traffic detected
exceeds the upper threshold or
drops down below the lower
threshold from a point higher
than the upper threshold

storm-constrain enable trap

Optional

By default, the system sends
trap messages when the traffic
detected exceeds the upper
threshold or drops down below
the lower threshold from a point
higher than the upper
threshold.

Specify to send log when the
traffic detected exceeds the
upper threshold or drops down
below the lower threshold from
a point higher than the upper
threshold

storm-constrain enable log

Optional

By default, the system sends
log when the traffic detected
exceeds the upper threshold or
drops down below the lower
threshold from a point higher
than the upper threshold.

z

For network stability sake, configure the interval for generating traffic statistics to a value that is not

shorter than the default.

z

The storm constrain function, after being enabled, requires a complete statistical period (specified

by the storm-constrain interval command) to collect traffic data, and analyzes the data in the next

period. Thus, it is normal that a period longer than one statistic period is waited for a control action

to happen if you enable the function while the packet storm is present. However, the action will be

taken within two periods.

z

The storm constrain function is applicable to unicast packets, multicast packets, and broadcast

packets; and you can specify the upper and lower threshold for any of the three types of packets.

Setting the Interval for Collecting Ethernet Port Statistics

You can use the reset counters interface command to clear interface statistics.

Follow these steps to configure the interval for collecting interface statistics:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter Ethernet port view

interface interface-type
interface-number

Configure the interval for
collecting interface statistics

flow-interval interval

Optional

The default interval for
collecting interface statistics is
300 seconds.