beautypg.com

Classification of system information, Eight levels of system information – H3C Technologies H3C S5120 Series Switches User Manual

Page 645

background image

1-2

Figure 1-1 Information center diagram (default)

1

2

3

4

5

6

7

8

9

console

0

channel6

monitor

loghost

trapbuffer

logbuffer

snmpagent

channel7

channel8

channel9

Log

information

Trap

information

Debug

information

console

monitor

Log host

Trap buffer

Log buffer

Snmp agent

System

information

Information

channel

Output

destination

Syslog

By default, the information center is enabled. An enabled information center affects the system

performance in some degree due to information classification and output. Such impact becomes more

obvious in the event that there is enormous information waiting for processing.

Classification of System Information

The system information of the information center falls into three types:

z

Log information

z

Trap information

z

Debugging information

Eight Levels of System Information

The information is classified into eight levels by severity. The severity levels in the descending order are

emergency, alert, critical, error, warning, notice, informational and debug. When the system information

is output by level, the information with severity level higher than or equal to the specified level is output.

For example, in the output rule, if you configure to output information with severity level being

informational, the information with severity level being emergency through informational will be output.