beautypg.com

Configuration prerequisites – H3C Technologies H3C S7500E Series Switches User Manual

Page 64

background image

3-25

To do…

Use the command…

Remarks

Set the idle-timeout

timer

idle-timeout minutes

[ seconds ]

Optional

The default idle-timeout is 10

minutes for all user interfaces.

The system automatically

terminates the user’s connection if

there is no information interaction

between the device and the user in

timeout time.

Setting idle-timeout to 0 disables

the timer.

Specify a command

to be automatically

executed when a user

logs in to the current

user interface

auto-execute command

command

Optional

By default, command

auto-execution is disabled.

The system automatically executes

the specified command when a

user logs in to the user interface,

and tears down the user

connection after the command is

executed. If the command triggers

another task, the system does not

tear down the user connection until

the task is completed. A telnet

command is usually specified to

enable the user to automatically

telnet to the specified device.

The auto-execute command command may disable you from configuring the system through the

user interface to which the command is applied. Therefore, before configuring the command and

saving the configuration (by using the save command), make sure that you can access the device

through VTY, TTY, console, or AUX interfaces to remove the configuration when a problem occurs.

Configuring the Device to Log In to Another Device as a Telnet Client

Configuration prerequisites

You have logged in to the device.