11-6
Configuration
System clock displayed by the
display clock command
Example
If the value of the original system
clock ± “zone-offset” is in the
summer-time range, the system
clock configured is the original
system clock ± “zone-offset”
+ ”summer-offset”.
Configure: clock datetime 1:00
2007/1/1, clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2
System clock configured: 02:00:00
zone-time Mon 01/01/2007
If the value of
"date-time"±"zone-offset" is not in
the summer-time range, the
system clock configured is
"date-time"±"zone-offset".
Configure: clock datetime 1:00
2007/1/1, clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
System clock configured: 04:00:00
ss Mon 01/01/2007
1, 2 and 3 or 1, 3 and 2
If the value of
"date-time"±"zone-offset" is in the
summer-time range, the system
clock configured is
"date-time"±"zone-offset"+”summe
r-offset”.
Configure: clock timezone
zone-time add 1, clock
summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2 and
clock datetime 1:00 2007/1/1
System clock configured: 01:00:00
zone-time Mon 01/01/2007