H3C Technologies H3C S7500E Series Switches User Manual

Page 52

background image

3-13

To do…

Use the command…

Remarks

Configure the

baud rate

speed speed-value

Optional

By default, the transmission rate is

9600 bps.

Transmission rate is the number of

bits that the device transmits to the

terminal per second.

Configure the

parity check mode

parity { even | mark | none | odd

| space }

Optional

none by default.

Configure the stop

bits

stopbits { 1 | 1.5 | 2 }

Optional

By default, the stop bits of the

console port is 1.

Stop bits are the last bits transmitted

in data transmission to

unequivocally indicate the end of a

character. The more the bits are, the

slower the transmission is.

Configure the data

bits

databits { 5 | 6 | 7 | 8 }

Optional

By default, the data bits of the

console port is 8.

Data bits is the number of bits

representing one character. The

setting depends on the contexts to

be transmitted. For example, you

can set it to 7 if standard ASCII

characters are to be sent, and set it

to 8 if extended ASCII characters

are to be sent.

Define a shortcut

key for enabling a

terminal session

activation-key character

Optional

By default, you can press Enter to

enable a terminal session.

Define a shortcut

key for terminating

tasks

escape-key { default | character }

Optional

By default, you can press Ctrl+C to

terminate a task.

Configure

AUX user

interface

view

properties

Configure the flow

control mode

flow-control { hardware | none |

software }

Optional

By default, the value is none