H3C Technologies H3C S7500E Series Switches User Manual
Page 167
11-5
Configuration
System clock displayed by the
display clock command
Example
If date-time is in the daylight
saving time range, the system
clock configured is “date-time” +
“summer-offset”.
Configure: clock datetime 8:00
2007/1/1 and clock summer-time
ss one-off 1:00 2007/1/1 1:00
2007/8/8 2
System clock configured: 10:00:00
ss Mon 01/01/2007
If date-time is not in the daylight
saving time range, the system
clock configured is date-time.
Configure: clock summer-time ss
one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
1:00 2008/1/1
System clock configured: 01:00:00
UTC Tue 01/01/2008
Configure: clock summer-time ss
one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
1:30 2007/1/1
System clock configured: 23:30:00
UTC Sun 12/31/2006
[1], 3 and 1
date-time is in the daylight saving
time range:
If the value of “date-time” -
“summer-offset” is not in the
summer-time range, the system
clock configured is “date-time” -
“summer-offset”;
If the value of “date-time” -
“summer-offset” is in the
summer-time range, the system
clock configured is date-time.
Configure: clock summer-time ss
one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
3:00 2007/1/1
System clock configured: 03:00:00
ss Mon 01/01/2007
Configure: clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
System clock configured: 02:00:00
zone-time Sat 01/01/2005
2 and 3 or 3 and 2
If the value of the original system
clock ± “zone-offset” is not in the
summer-time range, the system
clock configured is the original
system clock ± “zone-offset”.
Configure: clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2005/1/1 1:00 2005/8/8 2
System clock configured: 04:00:00
ss Sat 01/01/2005