11-4

Table 11-1 System clock configuration

Configuration

System clock displayed by the

display clock command

Example

1

date-time

Configure: clock datetime 1:00

2007/1/1

System clock configured: 01:00:00

UTC Mon 01/01/2007

2

The original system clock ±

zone-offset

Configure: clock timezone

zone-time add 1

System clock configured: 02:00:00

zone-time Sat 01/01/2005

1 and 2

date-time ± zone-offset

Configure: clock datetime 2:00

2007/2/2 and clock timezone

zone-time add 1

System clock configured: 03:00:00

zone-time Fri 02/02/2007

[1], 2 and 1

date-time

Configure: clock timezone

zone-time add 1 and clock

datetime 3:00 2007/3/3

System clock configured: 03:00:00

zone-time Sat 03/03/2007

If the original system clock is not in

the daylight saving time range, the

system clock configured is the

original system clock.

Configure: clock summer-time ss

one-off 1:00 2006/1/1 1:00

2006/8/8 2

System clock configured: 01:00:00

UTC Sat 01/01/2005

3

If the original system clock is in the

daylight saving time range, the

system clock configured is the

original system clock +

summer-offset.

Configure: clock summer-time ss

one-off 00:30 2005/1/1 1:00

2005/8/8 2

System clock configured: 03:00:00

ss Sat 01/01/2005

1 and 3

If date-time is not in the daylight

saving time range, the system

clock configured is date-time.

Configure: clock datetime 1:00

2007/1/1 and clock summer-time

ss one-off 1:00 2006/1/1 1:00

2006/8/8 2

System clock configured: 01:00:00

UTC Mon 01/01/2007