Configuration procedure – H3C Technologies H3C S10500 Series Switches User Manual
Page 438

423
Figure 108 Network diagram for IPv6 BIDIR-PIM configuration
Vlan-
in
t300
Device Interface IPv6
address
Device Interface IPv6
address
Switch A
Vlan-int100
1001::1/64
Switch D
Vlan-int300
4001::1/64
Vlan-int101 1002::1/64
Vlan-int400 5001::1/64
Switch
B Vlan-int200 2001::1/64
Vlan-int103 3001::2/64
Vlan-int101
1002::2/64
Source
1
- 1001::2/64
Vlan-int102
2002::1/64
Source
2
- 5001::2/64
Switch C
Vlan-int102
2002::2/64
Receiver 1
-
2001::2/64
Vlan-int103
3001::1/64
Receiver
2
- 4001::2/64
Loop0
6001::1/128
Configuration procedure
1.
Configure IPv6 forwarding, IPv6 addresses and the IPv6 unicast routing protocol.
Enable IPv6 forwarding on each switch, and configure the IPv6 address and prefix length for each
interface as per
. (Details not shown)
Configure OSPFv3 on the switches in the IPv6 BIDIR-PIM domain to ensure network-layer reachability
among them. (Details not shown)
2.
Enable IPv6 multicast routing, IPv6 PIM-SM, IPv6 BIDIR-PIM, and MLD.
# On Switch A, enable IPv6 multicast routing, enable IPv6 PIM-SM on each interface, and enable IPv6
BIDIR-PIM.
[SwitchA] multicast ipv6 routing-enable
[SwitchA] interface vlan-interface 100
[SwitchA-Vlan-interface100] pim ipv6 sm
[SwitchA-Vlan-interface100] quit
[SwitchA] interface vlan-interface 101
[SwitchA-Vlan-interface101] pim ipv6 sm
[SwitchA-Vlan-interface101] quit
[SwitchA] pim ipv6
[SwitchA-pim6] bidir-pim enable
[SwitchA-pim6] quit