Configuration procedures – H3C Technologies H3C S10500 Series Switches User Manual
Page 307

292
Figure 74 Network diagram for IPv6 multicast source/user control policy configuration
Configuration procedures
1.
Configure IP addresses for interfaces
Enable IPv6 forwarding and configure an IP address and prefix length for each interface as per
. (details not shown)
2.
Configure Switch A
# Create VLAN 101 through VLAN 104 and assign GigabitEthernet 1/0/1 through GigabitEthernet
1/0/4 to the four VLANs respectively.
[SwitchA] vlan 101
[SwitchA-vlan101] port gigabitethernet 1/0/1
[SwitchA-vlan101] quit
[SwitchA] vlan 102
[SwitchA-vlan102] port gigabitethernet 1/0/2
[SwitchA-vlan102] quit
[SwitchA] vlan 103
[SwitchA-vlan103] port gigabitethernet 1/0/3
[SwitchA-vlan103] quit
[SwitchA] vlan 104
[SwitchA-vlan104] port gigabitethernet 1/0/4
[SwitchA-vlan104] quit
# Enable IPv6 multicast routing. Enable IPv6 PIM-DM on VLAN-interface 101, VLAN-interface 102 and
VLAN-interface 104, and enable MLD on VLAN-interface 104.
[SwitchA] multicast ipv6 routing-enable
[SwitchA] interface vlan-interface 101
[SwitchA-Vlan-interface101] pim ipv6 dm
[SwitchA-Vlan-interface101] quit
[SwitchA] interface vlan-interface 102
[SwitchA-Vlan-interface102] pim ipv6 dm
[SwitchA-Vlan-interface102] quit