W A N s u i t e 6 4 5 0

ES

Sets the Errored Seconds (ES) threshold. An ES is a 1-second period in which
at least one logic error occurred. The default value is 45 seconds.

SES

Sets the Severely Errored Seconds (SES) threshold. An SES is a 1-second
period in which at least 320 CRC errors or one Out -of-Frame (OOF) error
occurred. The default value is 5 seconds.

LOSS

Sets the Loss of Signal Seconds (LOSS) threshold. A LOSS is 1-second
period in which the T1/E1 received signal is interrupted. The default value is
5 seconds.

UAS

Sets the Unavailable Seconds (UAS) threshold. A UAS is a 1-second period
in which consecutive severely errored seconds cause an unavailable state. The
default is 0 seconds (Disabled).

CSS

Sets the Controlled Slip Seconds (CSS) threshold. The default is 0 seconds
(Disabled).

BPVS

Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a 1-
second period in which at least one bipolar violation occurred. The default is
0 seconds (Disabled).

OOFS

Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default value is 5 seconds.

AISS

Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a 1-
second period when unframed all ones are received. The default is 0 seconds
(Disabled).

RAS

Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by
the terminal equipment when an improper signal is received from the facility
(or upon receipt of unframed all ones). The default is 0 seconds (Disabled).

Reset Timer

Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of “000” means the
alarm will never be reset.

The CBR screens provide the user-activated buttons described below.

CAUTION:

Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.

Button

Function

Submit

Sets any values that have been changed.

Clear Alarms

Resets the alarm conditions and counts to zero.

Performance

Displays a Performance/Summary screen that shows a current
count of the number of error events that have occurred over the
past 24 hours and the past 30 days.