beautypg.com

Error status and alarm thresholds table, Error status and alarm thresholds table -18 – Verilink WANsuite 6450 (34-00326) Product Manual User Manual

Page 126

background image

4-18

W A N s u i t e 6 4 5 0

NOTICE:

To set unit to Signaling mode, you must first configure the following: on
the CBR Configuration screen (page 4-17),
configure Framing, on the
Channel Table Details screen (page 4-40)
,set “Rate” to 56k/SIG, and on
the CES Service Details screen (page 4-36),
configure AAL1 Format.

T1/E1 Coding

Sets the CBR interface line coding.

Values: HDB3, AMI, B8ZS
Default: HDB3

NOTICE:

For a T1 CBR Maintenance Reset, the default is T1 ESF. The T1/E1
coding default is B8ZS.

T1 PRM

Lets you establish which performance messaging standard will be employed
to initiate Performance Report Message (PRM) functions. Setting this field to
“Enable” instructs the unit to use ANSI T1.403, which sends a PRM once
every second. Setting this field to “Disable” instructs the unit to use AT&T
TR54016, which provides performance reporting on request only.

Values: Disable, Enable
Default: Disable

T1 Zero Suppress

Determines whether ones density insertion is activated after 15 zeros. This
parameter is ignored if the Coding parameter is set to “B8ZS.”

Values: Disable, Enable
Default: Disable

T1 Mode

As a T1, the unit will operate in either long-haul or short-haul mode.

Values: Short-Haul, Long-Haul
Default: Short-Haul

T1/E1 Line Build Out

Sets the transmit Line Build Out (LBO) for the CBR interface.

Values: 0,

7.5,

15.0,

22.5 dB

Default: 0 dB

T1 DSX Level

Specifies the T1 DSX output level.

Values: 0

110, 111

220, 221

330, 331

440, 441

550, 551

660, >661 ft

Default: 0

−110

ft

E1 CRC4 Mode

Provides line integrity detection to determine if bit errors are present on the
line.

Values: Disable, Enable
Default: Disable

Error Status and Alarm Thresholds Table

The unit can be programmed to generate an alarm condition based on a
specific level of performance degradation. The CBR screen presents a table
that provides current error status and alarm threshold information.