4-12

W A N s u i t e 6 4 5 0

Alarm Profile Details Screen

Select from the column on the above screen to display a
screen similar to the one shown in Figure 4.11. The table on this screen lets
you configure the alarm threshold values to be used for the selected alarm
profile.

Figure 4.11

Alarm Profile Details Screen

Profile Name

Displays the name associated with this Endpoint Alarm profile.

Loop Attenuation

Sets the loop attenuation alarm threshold. If the current value reaches or
exceeds this threshold, a crossing trap is generated. A value of 0 (zero)
disables the trap.

SNR Margin

Sets the Signal-to-Noise Ratio margin alarm threshold. When the current SNR
value reaches or drops below this threshold, a crossing trap is generated. A
value of 0 (zero) disables the trap.

ES

Sets the threshold for the number of Errored Seconds within any given 15-
minute performance data collection interval. If the value of ES in a particular
15-minute collection interval reaches/ exceeds this value, a trap is generated.
One trap will be sent per interval per endpoint. A value of 0 (zero) disables
the trap.

SES

Sets the threshold for the number of Severely Errored Seconds within any
given 15-minute performance data collection interval. If the value of SES in a
particular 15-minute collection interval reaches/exceeds this value, a trap is
generated. One trap will be sent per interval per endpoint. A value of 0 (zero)
disables the trap.

CRC

Sets the threshold for the number of Cyclic Redundancy Check anomalies
within any given 15-minute performance data collection interval. If the value
of CRC anomalies in a particular 15-minute collection interval reaches/
exceeds this value, a trap is generated. One trap will be sent per interval per
endpoint. A value of 0 (zero) disables the trap.